3 [settings] [homing parameters, Settings] [homing parameters – Festo Контроллеры двигателя SFC-LAC User Manual

Page 78

Advertising
background image

4. The control panel (only type SFC−LACI−...−H2)

4−14

Festo GDCP−SFC−LACI−IO−EN en 0812NH

4.5.3

[Settings] [Homing parameters]

Setting the homing method and the speed during reference
travel.

·

Observe the instructions in chapter 5.2.1.

[Hom. paramet.] Param.

Description

[Homing method]

switch negative

Homing to the integrated
reference switch at the
retracted end position with
index search

block negative

Homing to a negative fixed
stop

block positive

Homing to positive fixed
stop

Note: Further homing run methods can only be
configured via FCT.

[Velocity v_rp]

v_rp

Speed when searching for
the reference point

[Velocity v_zp]

v_zp

Speed when moving to the
axis zero point

[SAVE...]

Save parameters in EEPROM

Note
A new homing run must always be carried out after modifyĆ
ing the homing run method.

The maximum speed for homing is subject to built−in limits.