background image

5. Commissioning

5−24

Festo GDCP−SFC−LACI−IO−EN en 0812NH

5.4

Functional test

Warning
There is a danger of injury.

Faults in parametrisation can cause injury to human beings
and damage to property.

·

Enable the controller only if the axis system has been
correctly installed and parametrised.

To allow the SFC−LACI to be controlled via the controller
interface, you must deactivate the manual device control:

ć

Via the SFC−LACI control panel using the menu command
[HMIĂcontrol] (HMI = off).

ć

With the FCT in the Project output" window under Device
control" (FCT control).

In order to check the configuration and axis set−up, first enter
a simple test program or simulate the control by directly setĆ
ting the inputs.

·

Please observe the functional description of the controller
interface in section 5.5.1.

·

Provide the necessary system inputs on the SFC−LACI.
There must be a 1−signal at the ENABLE and STOP inputs
(enable controller and power output stage).

·

Observe also the output signals. Logic 1 is at the READY
output (ready status) if the controller and the output
stage are enabled and no error has been detected.

·

Parameterise and start the homing run as well as some
positioning motions.

·

Check the positioning behaviour.