4. The control panel (only type SFC−LACI−...−H2)

4−9

Festo GDCP−SFC−LACI−IO−EN en 0812NH

[Diagnostic] [...]

Description

[Axis parameter]

v max

Maximum speed

x neg

Stroke limitation: Software end position, negative

x pos

Stroke limitation: Software end position, positive

x zp

Offset axis zero point

Tool load

Tool load (e.Ăg. a gripper on the front plate or on the
piston rod)

[System paramet.]

Load Power

Load voltage ok?

VDig

Digital voltage (= Logic voltage) [V]

I max

Max. phase current [A]

P_Pos

Average power during last positioning procedure [W]

t_Pos

Time taken for the last positioning procedure [s]

Cycle

Number of positioning movements

Mode

Unit of measurement [mm]

Hom.meth.

The parametrised homing method:
Ĉ RefS.n: Reference switch in negative direction
Ĉ RefS.p: Reference switch in positive direction
Ĉ Bl.pos: Fixed stop in positive direction
Ĉ Bl.neg: Fixed stop in negative direction
Ĉ LimS.p: Limit switch in positive direction
Ĉ LimS.n: Limit switch in negative direction

Ref. switch

Activated (switching) position of the parametrised referĆ
ence switch

Neg. Lim−Sw

Activated (switching) position of the negative limit switch

Pos. Lim−Sw

Activated (switching) position of the positive limit switch

T_Motor

Temperature of the linear motor [°C]

T_LACI

Temperature of the SFC−LACI [°C]

[SW information]

SFC−LACI firmware version

Tab. 4/3: [Diagnostic] menu