5. Commissioning
5−31
Festo GDCP−SFC−LACI−IO−EN en 0812NH
MC: O1
Motion Complete
Output
Status
MC (output)
O1
Logic 0
Ĉ Positioning procedure is being carried
out.
Ĉ There is an error (if ERR = 0).
Logic 1
Ĉ Positioning procedure complete (actual
position is within the target window,
see CI object 6067
h
), or
Ĉ Nominal position = actual position (if no
enable set).
READY: O2
Ready for operation, all preconditions for starting a positionĆ
ing procedure have been met.
Output
Status
READY (output)
O2
Logic 0
System is not ready to operate.
Ĉ Logic 0 is active at ENABLE or
Ĉ there is an error or
Ĉ logic 0 is active at STOP.
Logic 1
System is ready for operation.
Ĉ Logic 1 is active at ENABLE and
Ĉ there is no error and
Ĉ logic 1 is active at STOP.