Overview of cables – Festo Контроллеры двигателя SFC-LAC User Manual
Page 47
3. Installation
3−5
Festo GDCP−SFC−LACI−IO−EN en 0812NH
If unused plug connectors are touched, there is a danger that
damage may occur to the SFC−LACI or to other parts of the
system as a result of ESD (electrostatic discharge). Place proĆ
tective caps on unused terminal connections in order to preĆ
vent such discharges.
Overview of cables
Connection
Cable
Type
1
Parametrising interface
Programming cable
KDI−MC−M8−SUB−9−2.5
2
Controller interface
Pilot line
KES−MC−1−SUB−15−...
3
Power supply
Power supply cable
KPWR−MC−1−SUB−15HC−...
5
Local digital I/Os
Connecting cable
KM8−M8−... or NEBU−M8−...
6
Motor connection
Motor cable
NEBM−T1G6−T1G6−...
Encoder cable
NEBM−T1G12−T1G12−...
Tab. 3/2: Overview of cables (accessories)
For complying with the IP protection class:
·
Tighten the union nuts/locking screws on the plugs by
hand.
·
Seal unused M8 connections with type ISK−M8 protective
caps (accessories).
Observe the tightening torques specified in the
documentation for the cables and plugs used.