Festo Контроллеры двигателя SFC-LAC User Manual
Page 234
![background image](/manuals/464475/234/background.png)
B. Supplementary information
B−72
Festo GDCP−SFC−LACI−IO−EN en 0812NH
Drive data
CI
6510h
Record
Description
SFC−LACI data
Output stage
temp
6510h
1h
int16
r
temp.
See 31h.
Output stage
max temp
6510h
2h
int16
r
max. temp.
See 32h.
Max. current
6510h
4h
uint16
rw
See 41h.
Device control 6510h
6h
uint16
rw
See 43h.
Controller serial
number
6510h
7h
uint32
r
number
See A0h.
Limit switch
polarity
6510h
11h
int16
rw
polarity
Limit switch type: 0 = no limit switch, 1 = N/C contact, 2 = N/O contact
Limit switch
selector
6510h
12h
int16
rw
selector
0 none
1 IN0 = limit switch negative
IN1 = limit switch positive
2 IN0 = limit switch positive
IN1 = limit switch negative
3 IN0 = limit switch negative
IN2 = limit switch positive
4 IN0 = limit switch positive
IN2 = limit switch negative
5 IN1 = limit switch negative
IN2 = limit switch positive
6 IN1 = limit switch positive
IN2 = limit switch negative
Homing switch
selector
6510h
13h
int16
rw
selector
Selection of reference switch: 0 = none, 1 = IN0, 2 = IN1, 3 = IN2