4. The control panel (only type SFC−LACI−...−H2)

4−15

Festo GDCP−SFC−LACI−IO−EN en 0812NH

4.5.4

[Settings] [Position set]

Parametrising the position set table

·

Observe the instructions in section 5.2.7.

·

Select first the number of the desired positioning record.
The following settings refer to the currently selected posiĆ
tioning record.

[Position set]

Param.

Description

[Position nr]

No.

Number of the positioning record [1...31]

[Pos set mode]

[absolute/
relative]

Positioning mode
absolute = Position specification refers to the project zero point
relative = Position specification refers to the current position
e = energy−optimized path generator

[Position]

*)

xt

Target position in [mm]

[Velocity]

vel

Positioning speed in [mm/s]

[Acceleration]

a

Acceleration in [mm/s

2

]

[Deceleration]

d

Deceleration in [mm/s

2

]

[Jerk Acc]

Yes

Acceleration jerk in [m/s

3

]

[Jerk Dec]

jd

Deceleration jerk in [m/s

3

]

[Work load]

m

Applied load (= workpiece mass) in [g]

Time MC

t_MC

Damping time (time between reaching the target window and
setting Motion Complete")

[SAVE...]

Saves parameters to the EEPROM

*)