Festo Контроллеры двигателя SFC-LAC User Manual

Page 209

Advertising
background image

B. Supplementary information

B−47

Festo GDCP−SFC−LACI−IO−EN en 0812NH

Teach target

CI

21FCh

00h

Var

uint8

rw

Description

The parameter that is described in the next teach command with the actual
position:
1: The currently selected positioning record (see 2032h)
2: Axis zero point
3: Project zero point
4: Lower software end position
5: Upper software end position

Homing required

CI

23F6h

00h

Var

uint8

r

Description

Defines whether or not homing must be carried out after switching on (or after
the logic voltage supply has failed) in order to carry out positioning tasks.
Fixed = 0: Homing run must be carried out

Homing max. torque/force

CI

23F7h

00h

Var

uint8

rw

Description

Maximum force during homing in [%]. Value range: 10...100.