B. Supplementary information

B−21

Festo GDCP−SFC−LACI−IO−EN en 0812NH

Record number FHPP

CI

2033h

01h...03h

Array

uint8

r(w)

Description

FHPP record number

Record number

01h

rw

Record pointer for positioning and teaching.
It is also valid when the drive is not in Record Select mode (e.Ăg. during teaĆ
ching). For record selection this parameter is transferred in the cyclic I/O data.
Value range: 0 ... 34 (0x00 ... 0x22).
Values:
0 (0x00): Homing (positioning record 0)
1 (0x01): Positioning record 1
2 (0x02): Positioning record 2
...:

Positioning record ...

31 (0x1F): Positioning record 31
32 (0x20): Inching mode
33 (0x21): (reserved)
34 (0x22): FCT positioning record

Active record

02h

r

The number of the active record. relevant for record chaining.

Record status byte

03h

r

Contains FHPP status byte 4 with information on record chaining.
(see section 5.5.3).

Note: The object 2032h is provided for access via CI.

Standstill position window

CI

2040h

00h

Var

uint32

rw

Description

Standstill position window in [increments]: Amount by which the drive may
move after Motion Complete", until the standstill monitoring responds.