B. Supplementary information

B−67

Festo GDCP−SFC−LACI−IO−EN en 0812NH

Position control parameter set

Caution: Risk of injury to people and damage to property.
The factory settings for the controller parameters should only be modified in
exceptional cases. Unfavourable settings can lead to uncontrollable behaviour
of the entire system.

·

Only change the controller parameters with the aid of FCT.

·

Follow the instructions in FCT for the controller parameters.

CI

60FBh

12h...15h

Array

int32

rw

Description

Controller parameters

Position controller:

closed loop

60FBh

12h

closed loop

natural frequency Position controller: circuit frequency. Value range: 1...1000

Position controller:

damping

60FBh

13h

damping

Position controller: damping. Value range: 100...5000

Current controller:

gain

60FBh

14h

gain

Current controller: gain. Value range: 100...10000

Current controller:

integrating time

60FBh

15h

integrating time

constant Current controller: I−share Value range: 1...15000

Digital inputs

CI

60FDh

00h

Var

uint32

r

Description

Mapping the digital inputs
Bit 0:

Negative limit switch

Bit 1:

Positive limit switch

Bit 2

Reference switch

Bit 3...15:

Reserved (= 0)

Bit 16...20:

Current record number

Bit 21:

STOP

Bit 22:

ENABLE

Bit 23:

START

Bit 24:

Sample input

Bit 25...31:

Reserved (= 0)