Festo Контроллеры двигателя SFC-LAC User Manual
Page 128
5. Commissioning
5−46
Festo GDCP−SFC−LACI−IO−EN en 0812NH
Overview of the parameters for the local digital outputs Out 1/2
Parameter / Description
FCT
CI
Out 1/2: Status of the outputs (set / not set)
Bit
Value
Display
0
0x00000001
Status Brake
25
0x02000000
Status Out1
26
0x04000000
Status Out2
x
60FE/01h
Out 1/2: Mask
Bit
Value
Function
25
0x02000000
Activates the display of Out1 in 60FE/01h
26
0x04000000
Activates the display of Out2 in 60FE/01h
ć
60FE/02h
Out 1: Use
Value
Out 1 is used as:
0
No function
1
Brake output (see 5.5.6)
2
Digital signal display" (see FCT)
3
Output/Compare" (see FCT)
x
2421/01h
Out 1: Setting condition
Value
The output is set dependent upon:
1
Position comparison
2
Force comparison
3
Speed comparison
4
Record number comparison
10h
Ready
11h
Motion Complete
12h
Error
13h
Sample in
14h
(reserved)
15h
ON (during setting of this bit, the output is set immediately)
x
2421/02h
Out 1: Resetting condition (delay: see 2421/08h)
Value
The output is reset dependent upon:
1
Position comparison + delay
2
Force comparison + delay
3
Speed comparison + delay
4
Record number comparison + delay
10h
Ready + delay
11h
Motion Complete + delay
12h
Error + delay
13h
Sample in + delay
14h
Delay
15h
OFF (during setting of this bit, the output is reset immediately)
x
2421/03h