B. Supplementary information

B−10

Festo GDCP−SFC−LACI−IO−EN en 0812NH

B.1.5

Checking the data

Permitted value ranges

Transferred parameters and values are checked by the
SFC−LACI before being accepted.

Note
In the case of invalid parameters or values, an error messĆ
age will not appear in the response; rather, the received
value will always be returned (Echo).

Recommendation:
Check that values have been written correctly by downloadĆ
ing the current contents of the object with a subsequent Read
command.

Note
The following applies when writing the objects:

Ĉ Discrete values (values from a value list):

an invalid value will not be accepted; the previously
valid value will be retained.

Ĉ Continuous values (e.g. lengths, speeds, etc.): an imperĆ

missible value will be limited to the nearest permitted
value.

Error messages

If there are faults in the commands (e.Ăg. syntax faults, transĆ
mission errors), the value <0x00FF> will be transmitted (object
2FF0h) instead of the usual reply. Possible causes:

ć

Incorrect initial character, separating character or empty
character

ć

Incorrect hex digit

ć

Incorrect value type