Mdio frame format (clause 45), Mdio frame format (clause 45) -2, The port address – Altera Embedded Peripherals IP User Manual

Page 152: The device address

Advertising
background image

MDIO Frame Format (Clause 45)

The MDIO core communicates with the external PHY device using frames. A complete frame is 64 bits

long and consists of 32-bit preamble, 14-bit command, 2-bit bus direction change, and 16-bit data. Each

bit is transferred on the rising edge of the management data clock (MDC). The PHY management

interface supports the standard MDIO specification (IEEE802.3 Ethernet Standard Clause 45).

Figure 15-2: MDIO Frame Format (Clause 45)

Z0 Read
10 Address/W

rite

PRE

ST

OP

PRTAD

DEVAD

TA

REGAD/Data

Idle

00 Address
01 Write
11 Read

32 bits

2 bits

2 bits

5 bits

5 bits

2 bits

16 bits

1 bit

Table 15-1: MDIO Frame Field Descriptions—Clause 45

Field

Name

Description

PRE

Preamble. 32 bits of logical 1 sent prior to every transaction.

ST

The start of frame for indirect access cycles is indicated by the <00> pattern. This pattern

assures a transition from the default one and identifies the frame as an indirect access.

OP

The operation code field indicates the following transaction types:
00 indicates that the frame payload contains the address of the register to access.
01 indicates that the frame payload contains data to be written to the register whose

address was provided in the previous address frame.
11 indicates that the frame is a read operation.
The post-read-increment-address operation <10> is not supported in this frame.

PRTAD

The port address (

PRTAD

) is 5 bits, allowing 32 unique port addresses. Transmission is

MSB to LSB. A station management entity (STA) must have a prior knowledge of the

appropriate port address for each port to which it is attached, whether connected to a

single port or to multiple ports.

DEVAD

The device address (

DEVAD

) is 5 bits, allowing 32 unique MDIO manageable devices

(MMDs) per port. Transmission is MSB to LSB.

TA

The turnaround time is a 2-bit time spacing between the device address field and the

data field of a management frame to avoid contention during a read transaction.
For a read transaction, both the STA and the MMD remain in a high-impedance state

(Z) for the first bit time of the turnaround. The MMD drives a 0 during the second bit

time of the turnaround of a read or postread-increment-address transaction.
For a write or address transaction, the STA drives a 1 for the first bit time of the

turnaround and a 0 for the second bit time of the turnaround.