Usage Set the monitor destination port, i.e., the mirror port.

Use ”show destination” to show currently configured port monitoring des-
tination port.

Default values By default there is no destination port.

7.3.38

Set Monitored Ports

Syntax [no] source <PORTLIST> [ingress] [egress]

Context

Port Monitoring

context

Usage Add/delete/update monitor source port(s), i.e., the ports being monitored.

Use ”show source” to show current set of ports being monitored.

Default values By default there are no source ports. Commands apply both to

”ingress” and ”egress” if neither is specified.

7.3.39

Manage LLDP settings

Syntax [no] lldp

Context

Global Configuration

context.

Usage Enter

LLDP Configuration

context. Use ”no lldp” to disable lldp.

Use ”show lldp” to view the current configuration. Alternatively, you can
enter the

LLDP Configuration

context and run ”show” (see example in

sec-

tion 7.3.40

).

Default values LLDP is enabled by default.

7.3.40

Enable/disable LLDP

Syntax [no] enable

Context

LLDP Configuration

context.

Usage Enable/disable LLDP. Use ”enable” to enable and ”no enable” to disable

LLDP on all LAN ports. (As of WeOS v4.17.0 ”no enable” will be stored as