Westermo OS Management Guide

Version 4.17.0-0

Continued from previous page

Enabled

To enable the trigger - check the box, to disable un-
check the box.

Severity Active

Severity level when active

Severity Inactive

Severity level when inactive

Condition

Controls the condition for triggering (High/low)

Sensors

The sensor source for this trigger

Threshold Rising

The Rising threshold is the higher threshold value for
the sensor. When the current sample value is higher
than this value, and the last sample was lower than
this value, an action is triggered. Valid for none binary
sensors such as temperature and SNR.

Threshold Falling

The falling threshold is the lower threshold value for
the sensor. When the current sample value is less than
this value, and the last sample was greater than this
value, an action is triggered. Valid for none binary sen-
sors such as temperature and SNR.

Action

Selects the action for the trigger

Port

The ports on your switch is grouped as on the actual
hardware, in slots. To get alarms for a a specific port,
check the check-box located underneath the port label.
In the picture above you see ports 1/1, 1/2 and 2/1 are
marked as alarm sources for this link alarm trigger.