Example – Westermo RedFox Series User Manual
Page 561
Westermo OS Management Guide
Version 4.17.0-0
Additional settings for digital-in triggers are listed below.
❼ Ring: By default, FRNT ring ID 1 is used (as of WeOS v4.17.0 only
a single FRNT ring is supported, thus other values are invalid.) Use
”show env” (in Admin Exec context) to list available sensors, see
❼ Condition: By default, the alarm condition is set to down (or low). That
is, ring status up (high) is considered normal and ring down (low) is
considered an alarm situation.
❼ Enable/Disable: By default, the trigger is enabled.
❼ Severity: By default, active severity is WARNING and inactive severity
is NOTIFY.
❼ Action: By default, the trigger is mapped to the default action profile
(action 1).
Example
example:/#> configure
example:/config/#> alarm
example:/config/alarm/#> trigger frnt
example:/config/alarm/trigger-2/#> end
example:/config/alarm/#> show
Trigger
Type
Enabled
Action
Source
===============================================================================
1
power
YES
1
1 2
2
frnt
YES
1
Instance 1
Action
Targets
===============================================================================
1
snmp log led digout
===============================================================================
Summary alarm traps: Disabled
example:/config/alarm/#>
24.3.2.7
LFF Trigger Configuration Example
Note, this setting only applies to units equipped with SHDSL ports.
Syntax trigger lff
Context
context
Usage Create a Link Fault Forward (LFF) trigger, and enter the
context for this trigger.
➞ 2015 Westermo Teleindustri AB
561