Westermo OS Management Guide

Version 4.17.0-0

Additional settings for digital-in triggers are listed below.

❼ Ring: By default, FRNT ring ID 1 is used (as of WeOS v4.17.0 only

a single FRNT ring is supported, thus other values are invalid.) Use
”show env” (in Admin Exec context) to list available sensors, see

sec-

tion 7.3.50

.

❼ Condition: By default, the alarm condition is set to down (or low). That

is, ring status up (high) is considered normal and ring down (low) is
considered an alarm situation.

❼ Enable/Disable: By default, the trigger is enabled.
❼ Severity: By default, active severity is WARNING and inactive severity

is NOTIFY.

❼ Action: By default, the trigger is mapped to the default action profile

(action 1).

Example

example:/#> configure
example:/config/#> alarm
example:/config/alarm/#> trigger frnt
example:/config/alarm/trigger-2/#> end
example:/config/alarm/#> show
Trigger

Type

Enabled

Action

Source

===============================================================================

1

power

YES

1

1 2

2

frnt

YES

1

Instance 1

Action

Targets

===============================================================================

1

snmp log led digout

===============================================================================
Summary alarm traps: Disabled

example:/config/alarm/#>

24.3.2.7

LFF Trigger Configuration Example

Note, this setting only applies to units equipped with SHDSL ports.

Syntax trigger lff

Context

Alarm Configuration

context

Usage Create a Link Fault Forward (LFF) trigger, and enter the

Alarm Trigger

Configuration

context for this trigger.