Section 15.1.2.1 – Westermo RedFox Series User Manual

Page 327

Advertising
background image

Westermo OS Management Guide

Version 4.17.0-0

Note

It is possible to connect uplinks of a WeOS dual-homing switch to any layer-2
topology, but failover performance is optimised for FRNT rings.
When connecting uplinks to LAN topologies other than FRNT the synchro-
nised
option in dual-homing must be disabled, see

section 15.1.2.1

, other-

wise the uplinks will not come up.

Section 15.1.2.1

describes the synchronised dual-homing function, illustrates

how you can combine Multi-Link Dual-Homing and FRNT Ring Coupling, support-
ing topologies where you can connect the dual-homing uplinks to two adjacent
FRNT rings.

Section 15.1.2.2

presents the possibility of using multiple instances of dual-homing.

15.1.2.1

Synchronized Dual-Homing

WeOS Multi-Link Dual-Homing provides a mechanism referred to as synchronised
dual-homing
. Synchronised dual-homing has two purposes:

Integrity of the uplink: A dual-homing switch monitors uplink connectivity

by exchanging specific echo packets with the remote switch. This ensures
that a link break is detected even in cases where intermediate transceivers
do not propagate link down.

Define preferred uplink when connecting two adjacent FRNT rings: It is pos-

sible to connect the uplinks of a dual-homing node to two adjacent FRNT
rings, which in turn are connected by ring coupling. The synchronised dual-
homing feature will give preference to the uplink connected to a ring cou-
pling sub-ring, i.e., the ring containing the RiCo nodes. More details later in
this section.

If you wish to connect a dual-homing switch to topologies other than FRNT you
need to disable the synchronised dual-homing feature in the dual-homing node.
An example is given below where ports 1 and 2 are configured as uplinks to non-
FRNT nodes.

➞ 2015 Westermo Teleindustri AB

327