Sections 24.3.2.1, Example – Westermo RedFox Series User Manual

Page 555

Advertising
background image

Westermo OS Management Guide

Version 4.17.0-0

24.3.2.1

Link Alarm Trigger Configuration Example

Syntax trigger link-alarm

Context

Alarm Configuration

context

Usage Create a link-alarm trigger, and enter the

Alarm Trigger Configuration

context for this trigger.

Additional settings for link-alarm triggers are listed below. The only manda-
tory setting is the list of ports - no link-alarm alarm events will occur until
ports are defined.

❼ Port(s) (mandatory): Define the port or ports this link-alarm trigger is

associated with.

❼ Enable/Disable: By default, the trigger is enabled.

❼ Severity: By default, active severity is WARNING and inactive severity

is NOTIFY.

❼ Action: By default, the trigger is mapped to the default action profile

(action 1).

Example

example:/#> configure
example:/config/#> alarm
example:/config/alarm/#> trigger link-alarm
Created trigger 2
example:/config/alarm/trigger-2/#> port 1-2
example:/config/alarm/trigger-2/#> end
example:/config/alarm/#> show
Trigger

Type

Enabled

Action

Source

==============================================

1

power

YES

1

1 2

2

link-alarm

YES

1

1 2

Action

Targets

===============================================================================

1

snmp log led digout

===============================================================================
Summary alarm traps: Disabled

example:/config/alarm/#>

➞ 2015 Westermo Teleindustri AB

555