Section 24.3.14 – Westermo RedFox Series User Manual

Page 573

Advertising
background image

Westermo OS Management Guide

Version 4.17.0-0

Usage Create, remove or update an alarm action (profile). Use ”action <INDEX>”

to enter the

Alarm Action Configuration

context and create a new or update

an existing action.

Use ”no action <INDEX>” remove an existing action. The default action
(index 1) cannot be removed, but you can disable all targets.

Use command ”show action” to list all configured alarm action profiles, or
”show action <ID>” to show detailed configuration information on a spe-
cific action profile (also available as ”show” command within the

Alarm Ac-

tion Configuration

of that profile).

Default values Not applicable.

24.3.14

Manage Action Targets

Syntax [no] target <[log] [snmp] [led] [digout] [reboot] [custom]>

Context

Alarm Action Configuration

context

Usage Add or remove alarm target to an alarm action (profile).

❼ led: Set ON/Status LED
❼ log: Log status change to syslog
❼ snmp: Generate an SNMP trap
❼ digout: Control digital out relay
❼ reboot: Reboot the unit. USE WITH CAUTION!
❼ custom: Run any admin-exec level command. DEPRECATED!

Warning

The ”custom” target is for experimental purposes only! A .conf file con-
taining ”target custom” and ”custom reboot” (see

section 24.3.15

)

will be translated to ”target reboot” automatically. That is to be
backwards compatible. Other ”custom” commands are not guaranteed
to be supported in future releases.

Use command ”show target” to show the alarm target(s) configured for
this action profile.

Default values target log (New action profiles has ”target log” as default.

➞ 2015 Westermo Teleindustri AB

573