Display (A)

Flashing

Alarm Tone

Description

NO OPERATOR / NOT IN
PARK
ENGINE SHUTDOWN

Continuous tone

Operator not detected in seat
with header engaged or out of
N-DETENT with machine moving
at <5mph (8 km/h): engine
shutdown after 5 seconds

NO OPERATOR

Continuous tone

Engine shutdown when Operator
not detected in seat with machine
moving >5 mph (8 km/h)

NOT IN PARK

X

Short beep with each flash

GSL or interlock switches not
closed with key ON / engine OFF

PLACE GSL INTO “N”

Beeps at 2 per second until
corrected

GSL or interlock switches not
closed with key ON / engine OFF

SLOW DOWN

X

Short beep with each flash

Ground speed is greater than
or equal to 25 mph (40 km/h):
Operator should pull back on the
GSL to reduce ground speed

TRANS OIL PRESS

X

Continuous loud tone until oil
pressure is regained

Low transmission charge oil
pressure

TRANS OIL TEMP

X

Ongoing intermittent moderate
tone until temperature is below
acceptable level

Transmission oil temperature
above 221°F (105°C)

##.# LOW VOLTS

X

Single loud tone for 10 seconds Voltage below 11.5

##.# HIGH VOLTS

X

Single loud tone for 10 seconds Voltage above 15.5