MAINTENANCE AND SERVICING

Table 5.19 Relief Valve and Overload Settings

Header Model

Application/System

Windrower Differential

Relief Setting

(Header Attached)

psi (kPa)

Suggested Overload

Warning Setting

psi (kPa)

R80 and R85

Disc Pressure

5500 (37,921)

5000 (34,474)

Reel/Draper Pressure

2900 (19,994)

2500 (17,237)

D60, D65, and

A40-D

Knife/Conditioner

Pressure

4000 (27,579)

3600 (24,821)

Flow Control Blocks

Two hydraulic valve blocks with multiple cartridges are
used for the various windrower functions and are controlled
by the windrower control module (WCM) according to the
inputs from the Operator. The valve blocks are located
behind the left cab-forward side platform.

The valve blocks do NOT require any scheduled
maintenance other than to check for leaking fittings or
loose electrical connections. If service is required, contact
your MacDon Dealer.

Figure 5.207: Draper Header Hydraulics

Figure 5.208: Rotary Disc Header Hydraulics

169887