OPERATOR’S STATION

4. Press right (B) arrow to select Yes. Press SELECT (C).

• TO CALIBRATE SELECT is displayed in upper line

5. Press left (A) or right (B) arrow until HEADER TILT is

displayed on the lower line. Press SELECT (C).

• HDR TILT SENSOR CAL is displayed on the

upper line.

• EXTEND TILT TO START is displayed on the

lower line.

Figure 3.88: Calibrate Header Tilt

CAUTION

Check to be sure all bystanders have cleared the area.

6. Press and hold the HEADER TILT EXTEND (B) button

on the ground speed lever (GSL).

• CALIBRATING TILT is displayed on the upper line.

• EXTEND TILT HOLD is displayed on the lower line.

NOTE:
The word HOLD will flash during calibration. HEADER
TILT DONE will display on the lower line once calibration
is complete.

7. Release the HEADER TILT EXTEND (B) button.

• HEADER TILT SENSOR CAL is displayed on

upper line.

• PRESS RETRACT TILT is displayed on the

lower line.

Figure 3.89: Header Tilt Controls on Ground
Speed Lever