OPERATOR’S STATION

8. Press and hold HEADER TILT RETRACT (D) button

on GSL.

• CALIBRATING TILT is displayed on the upper line.

• RETRACT TILT HOLD is displayed on the

lower line.

NOTE:
The word HOLD will flash during calibration. HEADER
TILT COMPLETE will display on the lower line once
calibration is complete.

9. Release HEADER TILT RETRACT (D) button.

• TO CALIBRATE SELECT is displayed on the

upper line.

• HEADER TILT is displayed on the lower line.

10. Press right arrow to select next header sensor

calibration or STOP & EXIT. Press SELECT.
Refer to

Calibrating the Header Height Sensor, page

91

or

Calibrating the Header Float Sensor, page 95

.

11. Press PROGRAM to exit Programming Mode.

Figure 3.90: Header Tilt Controls on Ground
Speed Lever

Calibrating the Header Float Sensor

NOTE:

• Header MUST be attached to the windrower to perform this procedure. The cab display module (CDM)

automatically adjusts its programming for each header. For more information, refer to

4.5 Attaching and

Detaching Headers, page 202

.

• The Operator can use the left or right FLOAT buttons on the cab display module (CDM) to perform this procedure.

1. Turn ignition key to RUN, or start the engine. Refer to

Starting the Engine, page 152

.

2. Press PROGRAM (A) and SELECT (C) on cab display

module (CDM) to enter Programming Mode.

• WINDROWER SETUP? is displayed on the

upper line.

3. Press SELECT (C) until CALIBRATE SENSORS? is

displayed on the upper line.

• NO/YES is displayed on the lower line.

Figure 3.91: CDM Programming Buttons

169887

95

Revision A