Caution – MacDon M205 Operators Manual User Manual

Page 150

Advertising
background image

OPERATOR’S STATION

7. Press SELECT (B) until ACTIVATE HYD PURGE? is

displayed on the upper line.

• NO/YES is displayed on the lower line.

8. Press right (A) arrow to select YES. Press SELECT (B).

• TO ACTIVATE PURGE is displayed on the

upper line.

• PRESS AND HOLD is displayed on the lower line.

Figure 3.182: Activating Hydraulic Purge

CAUTION

Check to be sure all bystanders have cleared the area.

NOTE:
Holding the right arrow activates a timed purge cycle.
The CDM will jump to the exit menu if the arrow is
released before the end of the timed cycle.

9. Press and hold right (A) arrow to activate purge cycle.

• PURGE CYCLE STARTED will display on the

upper line.

10. When PURGE CYCLE ENDED is displayed release

right (A) arrow.

• NO EXIT YES is displayed on the lower line.

Figure 3.183: Activating Hydraulic Purge Cycle

11. Press right arrow to select YES. Press SELECT.

12. Press PROGRAM to exit Programming Mode or press

SELECT to proceed to next ACTIVATE FUNCTION.

Testing the Knife Drive Circuit using the Cab Display Module (CDM)

IMPORTANT:
Do not over speed a drive for a significant length of time. Doing so can lead to vibration, belt failures, or
other over speeding related problems.

NOTE:

• Header MUST be attached to windrower to follow this procedure. For more information, refer to

4.5 Attaching

and Detaching Headers, page 202

• Engine MUST be running to perform this procedure.

169887

134

Revision A

Advertising