OPERATOR’S STATION

Cab-Forward, Engine Running, Header Engaged, Draper Header, Index Switch ON

Scroll through display with cab display module (CDM) switch or ground speed lever (GSL) switch.

Display (lower or upper line)

Description

#####.# ENGINE HRS

Total engine operating time.

#####.# HEADER HRS

Total header operating time.

##.# ACRES/HOUR
##.# HECTARES/HOUR (if metric)

Actual cutting rate in acres (hectares)/hour.

###.# SUB ACRES
###.# SUB HECTARES (if metric)

Area cut since last reset. To reset, display SUB ACRES on lower line
and hold down program switch until display resets (5–7 Seconds).

###### TOTAL ACRES
###### TOTAL HECT (if metric)

Total area cut by machine.

##.## ##.# REEL IND
REEL.SENSOR

Reel peripheral speed along with ground speed in mph or km/h.
Sensor Disabled. IND and SENSOR alternate at 1 second intervals.

##.# ##.# DRAP INDX

Draper speed along with ground speed in mph or km/h.

#### KNIFE SPEED
#### KNIFE SENSOR

Knife speed in strokes per minute. Sensor Disabled.
SPEED and SENSOR alternate at 1 second intervals.

##.# HEADER HEIGHT
##.# HEADER SENSOR

Distance setting (00.0–10.0) between cutterbar and ground.
Sensor Disabled. HEIGHT and SENSOR alternate at 1 second
intervals.

##.# HEADER ANGLE
##.# HEADER SENSOR

Angle setting (00.0–10.0) header relative to ground.
Sensor Disabled. ANGLE and SENSOR alternate at 1 second intervals.

##.# L FLOAT R ##.#
FLOAT SENS DISABLED

Left and right float setting (0.0–10.0).
Sensor Disabled.

### °C or F HYD OIL TEMP
### °C or F HYD SENSOR

Hydraulic oil temperature.
Sensor Disabled. TEMP and SENSOR alternate at 1 second intervals.

LOAD|■■■■| | ####

Bar graph representing hydraulic operating pressure. Full scale
is pre-programmed overload pressure (2500–5000 psi). If sensor
disabled, LOAD does not display

4

##.# VOLTS

Engine electrical system operating voltage.

SCROLL
SUB-MENU (lower line only)
#### KNIFE SPEED
##.# HEADER HEIGHT
LOAD|■■■■|■■■■|
##.## ##.# REEL IND
##.# ##.# DRAP INDX

Displays sub-menu after 2–3 seconds. Press SELECT to cancel.
Scroll through sub-menu display with CDM switch.

##.## REEL MIN RPM (lower line)

Reel speed drops below programmed set-point.

MINIMUM (lower line)

Reel speed at zero ground speed.

4.

The LOAD sensor to monitor knife/conditioner circuit pressure is optional. To monitor reel/auger circuit pressure, relocate
sensor as per Form MD #169031, which is available through your Dealer.