OPERATOR’S STATION

4. Press right (B) arrow to select Yes. Press SELECT (C).

• TO CALIBRATE SELECT is displayed in upper line.

5. Press left (A) or right (B) arrow until HEADER HEIGHT

is displayed on the lower line. Press SELECT (C).

• CALIBRATING HEIGHT is displayed on the

upper line.

• RAISE HEADER HOLD is displayed on the

lower line.

Figure 3.84: Selecting Header Height
Calibration

CAUTION

Check to be sure all bystanders have cleared the area.

6. Press and hold the HEADER UP (C) button on the

ground speed lever (GSL).

• CALIBRATING HEIGHT is displayed on the

upper line.

• RAISE HEADER HOLD is displayed on the

lower line.

NOTE:
The word HOLD will flash during calibration. RAISE
HEADER DONE will display on the lower line once
calibration is complete.

7. Release the HEADER UP (C) button.

• HEIGHT SENSOR CAL is displayed on the

upper line.

• PRESS LOWER HEADER is displayed on the

lower line.

Figure 3.85: Header Height Controls on Ground
Speed Lever

169887