MAINTENANCE AND SERVICING

3. Locate the test port (A) which is located on the charge

filter head. Clean test port fitting and attach hose to
the fitting.

4. Start engine, and leave at idle. Pressure should be

270–300 psi (1862–2068) kPa) with the hydraulic oil at
100°F (40°C) minimum.

5. Note reading and shut down windrower.

6. If pressure is NOT within this range, contact your

MacDon Dealer.

7. Otherwise, remove hose from test port and close the

hood. Refer to

5.4.4 Closing Hood (Highest Position),

page 290

.

Figure 5.211: Charge Pump Test Port

169887