OPERATOR’S STATION

5. Press SELECT (D) until DISPLAY CONTRAST is

displayed on the upper line.

• Default setting is displayed on the lower line.

6. Press left (B) or right (C) arrows to adjust

display contrast.

7. Press PROGRAM (A) to exit Programming Mode or

press SELECT (D) to proceed to next CAB DISPLAY
SETUP? action.

Figure 3.82: Adjusting Display Contrast

3.18.7

Calibrating the Header Sensors

Sensor calibration programs the windrower control module (WCM) with settings for the attached header.

Calibrating the Header Height Sensor

NOTE:

• Header MUST be attached to the windrower to perform this procedure. The cab display module (CDM)

automatically adjusts its programming for each header. For more information, refer to

4.5 Attaching and

Detaching Headers, page 202

.

• Engine MUST be running to perform this procedure.

1. Start the engine. Refer to

Starting the Engine, page

152

.

2. Press PROGRAM (A) and SELECT (C) on cab display

module (CDM) to enter Programming Mode.

• WINDROWER SETUP? is displayed on the

upper line.

3. Press SELECT (C) until CALIBRATE SENSORS? is

displayed on the upper line.

• NO/YES is displayed on the lower line.

Figure 3.83: CDM Programming Buttons

169887

91

Revision A

Advertising