Detaching a D-Series Header: Hydraulic Center-Link

To detach a D-Series header from an M-Series windrower equipped with a hydraulic center-link, follow these steps:

DANGER

Stop engine and remove key from ignition before
leaving operator's seat for any reason. A child or
even a pet could engage an idling machine.

1. Start engine and press HEADER UP (A) switch to raise

header to maximum height.

2. Rephase cylinders if one end of the header does not

raise fully. If rephasing is needed, proceed as follows:

a. Press and hold the HEADER UP (A switch until

both cylinders stop moving.

b. Continue to hold the switch for 3–4 seconds.

Cylinders are phased.

3. Stop engine and remove key.

Figure 4.125: GSL

4. Pull lever (A) and rotate toward header to lower safety

prop (B) onto cylinder. Repeat for opposite cylinder.

Figure 4.126: Safety Prop