11troubleshooting windrower problems, Displaying the windrower and engine error codes, Troubleshooting windrower problems – MacDon M205 Operators Manual User Manual

Page 136: 11 troubleshooting windrower problems

Advertising
background image

OPERATOR’S STATION

6. Press left (B) or right (C) arrow to cycle between control

switch lock outs. The displayed control switches are as
follows:

• HEADER TILT

• HEADER FLOAT

• REEL FORE/AFT

• DRAPER SPEED

• AUGER SPEED

• KNIFE SPEED

• DISK SPEED

• REEL SPEED

NOTE:
Not all control locks apply to every header.

7. Press SELECT.

• EXIT VIEW LOCKOUTS? is displayed on the

upper line.

• NO/YES is displayed on the lower line.

8. Press right to select YES.

9. Press PROGRAM to exit Programming Mode or

press SELECT to proceed to next WINDROWER
SETUP action.

Figure 3.148: Cycle between Control Locks

3.18.11

Troubleshooting Windrower Problems

Displaying the Windrower and Engine Error Codes

NOTE:
Header MUST be attached to the windrower to perform this procedure. The cab display module (CDM)
automatically adjusts its programming for each header. For more information, refer to

4.5 Attaching and

Detaching Headers, page 202

.

1. Start the engine.

For more information, refer to

Starting the Engine,

page 152

.

2. Press PROGRAM (A) and SELECT (C) on cab display

module (CDM) to enter Programming Mode. Press
SELECT (C).

• WINDROWER SETUP? is displayed on the

upper line.

3. Press SELECT (C) until DIAGNOSTIC MODE? is

displayed in upper line.

• NO/YES is displayed on the lower line.

Figure 3.149: CDM Programming Buttons

169887

120

Revision A