MacDon M205 Operators Manual User Manual

Page 465

Advertising
background image

ENGINE ERROR CODES

J1939

SPN

J1939

FMI

Lamp

Color

Cummins

Code

J1939

SPN

Cummins

Description

Category

CDM Error

Message

3

Amber

386

516

Sensor supply voltage #1
circuit - Voltage above
normal, or shorted to high
source

1079

4

Amber

352

516

Sensor supply voltage
#1 circuit - Voltage below
normal, or shorted to low
source

3

Amber

227

Sensor supply voltage #2
circuit - Voltage above
normal, or shorted to high
source

1080

4

Amber

187

5 Volts DC

Supply

Sensor supply voltage
#2 circuit - Voltage below
normal, or shorted to low
source

5 Volts DC

Supply

3

Amber

697

Sensor Circuit

- Voltage

ECM internal temperature
sensor circuit - Voltage
above normal, or shorted
to high source

1136

4

Amber

698

ECM internal temperature
sensor circuit - Voltage
below normal, or shorted
to low source

Sensor

Circuit -

Voltage

3

Amber

691

Turbocharger #1
compressor inlet
temperature sensor circuit
- Voltage above normal, or
shorted to high source

1172

4

Amber

692

Turbocharger

#1Compressor

Inlet

Temperature

Turbocharger #1
compressor inlet
temperature sensor circuit
- Voltage below normal, or
shorted to low source

Turbocharger

#1Compressor

Inlet

Temperature

5

Amber

177

Turbo wastegate drive
current below normal

6

Turbo wastegate drive
current above normal

1188

7

Turbo

Wastegate

Turbo wastegate not
responding

Turbo

Wastegate

169887

449

Revision A