Transferring processlogix data, Transferring data to the r510.0 client, Transferring processlogix data -25 – Rockwell Automation 1757-SWKIT5100 ProcessLogix R510.0 Installation and Upgrade Guide User Manual

Page 151: Transferring data to the r510.0 client -25

Advertising
background image

Publication 1757-IN510A-EN-P - October 2003

ProcessLogix Client Installation and Upgrade Procedures 5-25

Transferring ProcessLogix
Data

Transferring Data to the R510.0 Client

1 . Logon to the R510.0 Client as ps_user.

2. Open Windows Explorer and confirm that the T: drive exists.

• If the T: drive exists, close Windows Explorer and skip

to Transfer Data on page 5-25.

• If the T: drive does not exist, close Windows Explorer and

continue with Remap the T: Drive on page 5-25.

Remap the T: Drive

3. Click Star t

Run.

4. Enter this command:


>cmd<


and click

OK to open the DOS window.

5. Enter >NET USE T: \\STN01\C$ /user:ps_user<


(where STN01 is the remote PC name and ps_user is the user
currently logged on to STN01.)


and press <Enter>.

6. If prompted, enter the appropriate password.

Transfer Data

7. Click Star t

Run.

8. Enter >cmd< and click OK to open the DOS window.

9. Enter >xcopy T:\UpgradeData\*.* C:\UpgradeData /E<


and press <Enter>.