Publication 1757-IN510A-EN-P - October 2003

5-32 ProcessLogix Client Installation and Upgrade Procedures

7. On the Connection tab, make these entries to have the Station

point to

SERVERB (PLX1 B):

a. Enter the name or IP address of

SERVERB (PLX1 B) in the

Server field.
PLX1 B is the default Server name assigned by the factory. It is
used for example purposes only.

b. Select the appropriate Station type option, Static Station or

Rotary Station.

c. Click

Advanced.

d. Enter the appropriate Static Station Number or enter the

appropriate update rates and startup display number for
Rotary.

e. Check the

Aux iliar y setup file checkbox.

f. Click

Br owse and navigate to

C:\Honeywell\Client\Station\default.stn and click

Open.

8. On the Displays tab, check the Sear ch subdir ector ies for

shapes checkbox.

9. Edit the Search for displays in list so that it includes the

following directories

only:

• C:\honeywell\client\system\r500
• C:\honeywell\client\abstract
• C:\honeywell\client\dspbld

a. To delete a directory, select it and click

Remove.

b. To add a directory, click

Add, click

, select the directory,

and click

OK.

1 0. Click Save.

1 1 . Click Yes to save the new connection.

1 2. Enter >defaultb.stn< in the File name field and click Save.

1 3. Select defaultb and click Connect.

IMPORTANT

You must indicate the full path to the .stn file.

TIP

Display Sear ch Path Optimization

You can improve Station’s performance by
unchecking the Search subdirectories for shapes
checkbox in the Connection Properties dialog box,
and then explicitly defining each subdirectory that
contains displays.