Saving r400.0 sp2 or r500.1 data to a remote pc, Networking an r400.0 sp2 or r500.1 server to a, Remote pc -13 – Rockwell Automation 1757-SWKIT5100 ProcessLogix R510.0 Installation and Upgrade Guide User Manual
Page 97
![background image](/manuals/579304/97/background.png)
Publication 1757-IN510A-EN-P - October 2003
ProcessLogix Server Upgrade Procedures 4-13
9. Close EvMove.
1 0. Remove the Master Disk and store it in a safe place.
Preparation for a ProcessLogix R400.0 SP2 or R500.1 to R510.0 Server
Upgrade is complete.
Return to the checklist that led you to this task.
Saving R400.0 SP2 or R500.1
Data to a Remote PC
Networking an R400.0 SP2 or R500.1 Server to a Remote PC
Use the following procedure to map a drive to a remote PC. If you
have a redundant server pair, you must complete this procedure on
SERVERB first. Then complete the entire procedure again on
SERVERA.
1 . If necessary, logon to the R400.0 SP2 or R500.1 Server as
ps_user.
2. Click Star t
⇒ Run.
3. Enter >cmd< and click OK to open the DOS window.
4. Enter >NET USE T: \\STN01\C$
/user:ps_user<
(where STN01 is the remote PC name and ps_user is the user
currently logged on to STN01) and press <Enter>.
5. If prompted, enter the appropriate password.
6. Open Windows Explorer and verify that the T: drive exists.