The ProcessLogix R510.0 Server contains enhancements which enable
connectivity to RSView SE with Process Extensions 3.10 and higher.
When connected via OPC, R510.0 populates the PE Navigation
application with ProcessLogix I/O modules and PID loops configured
in the ERDB. RSView PE standard faceplates can be used to view the
I/O modules and PID loops.

Additional Module Support

The following modules have been qualified for use with ProcessLogix:

• 1794-IB8
• 1794-IB32
• 1794-IC16
• 1794-IM8
• 1794-IRT8
• 1794-OB32
• 1794-OC16
• 1794-OM8

Navigate in Knowledge Builder to ProcessLogixR500

CCL Help

1794-FlexI/O for more information.