Rockwell Automation 1771-QDC PLASTIC MOLD.MODULE User Manual

Page 100

Advertising
background image

2–34

Command Word/Bit Descriptions

Publication 1771-6.5.88 – July 1997

Notes: 1. For [ ] engineering units, see page 3.

2. When using the Inject/Clamp/Eject mode, all pressure readings are system pressure at input 2, except where noted.

Ejector Full Retract Profile Setpoints

Word

Description

EPC33

Full Retract Segment 1 Velocity Setpoint [09] or [10]
if:

then the module:

you select Vel/Pos profile execution

controls ejector retract speed to this setpoint after starting any full retract portion of the
Ejector Profile until ejector position reaches the larger of EPC35 or EPC60

EPC03-B14 is RESET

reads this parameter in percent velocity

EPC03-B14 is SET

reads it in in.(mm)/s

EPC34

Full Retract Segment 1 Pressure Setpoint [03]
if:

then the module:

you select Press/Pos profile execution

controls ejector retract pressure to this setpoint after starting any full retract portion of
the Ejector Profile until ejector position reaches the larger of EPC35 or EPC60

EPC35

End of Full Retract Segment 1 Position Setpoint [16]

EPC36

Full Retract Segment 2 Velocity Setpoint [09] or [10]
if:

then the module:

you select Vel/Pos profile execution

controls ejector retract speed to this setpoint during any full retract portion of the
Ejector Profile from the ejector position EPC35 until ejector position reaches the larger
of EPC38 or EPC60

EPC03-B14 is RESET

reads this parameter in percent velocity

EPC03-B14 is SET

reads it in in.(mm)/s

EPC37

Full Retract Segment 2 Pressure Setpoint [03]
if:

then the module:

you select Press/Pos profile execution

controls ejector retract pressure to this setpoint during any full retract portion of the
Ejector Profile from the ejector position EPC35 until ejector position reaches the larger
of EPC38 or EPC60

EPC38

End of Full Retract Segment 2 Position Setpoint [16]

EPC39

Full Retract Segment 3 Velocity Setpoint [09] or [10]
if:

then the module:

you select Vel/Pos profile execution

controls ejector retract speed to this setpoint during any full retract
Ejector Profile from the ejector position EPC38 until ejector
position reaches EPC60

EPC03-B14 is RESET

reads this parameter in percent velocity

EPC03-B14 is SET

reads it in in.(mm)/s

EPC40

Full Retract Segment 3 Pressure Setpoint [03]
if:

then the module:

you select Press/Pos profile execution

controls ejector retract pressure to this setpoint during any full retract portion of the
Ejector Profile from the ejector position EPC38 until ejector position reaches EPC60

EPC41 -56

Reserved

Advertising