2–109

Command Word/Bit Descriptions

Publication 1771-6.5.88 – July 1997

TOC

Word

Description

TOC13

Output #5 Set-output Value during Profile [19]

TOC14

Output #6 Set-output Value during Profile [19]

TOC15

Output #7 Set-output Value during Profile [19]

TOC16

Output #8 Set-output Value during Profile [19]

Output Ramp Rates

The module uses the following ramp rates when moving its outputs
between setpoints during the Third Clamp Open Profile. The module
interprets a ramp rate of zero as a step function ramp (ramp disable).

Word

Description

TOC17

Output #1 Acceleration Ramp Rate during Profile [20]

TOC18

Output #2 Acceleration Ramp Rate during Profile [20]

TOC19

Output #3 Acceleration Ramp Rate during Profile [20]

TOC20

Output #4 Acceleration Ramp Rate during Profile [20]

TOC21

Output #5 Acceleration Ramp Rate during Profile [20]

TOC22

Output #6 Acceleration Ramp Rate during Profile [20]

TOC23

Output #7 Acceleration Ramp Rate during Profile [20]

TOC24

Output #8 Acceleration Ramp Rate during Profile [20]

TOC25

Output #1 Deceleration Ramp Rate during Profile [20]

TOC26

Output #2 Deceleration Ramp Rate during Profile [20]

TOC27

Output #3 Deceleration Ramp Rate during Profile [20]

TOC28

Output #4 Deceleration Ramp Rate during Profile [20]

TOC29

Output #5 Deceleration Ramp Rate during Profile [20]

TOC30

Output #6 Deceleration Ramp Rate during Profile [20]

TOC31

Output #7 Deceleration Ramp Rate during Profile [20]

TOC32

Output #8 Deceleration Ramp Rate during Profile [20]

End of Profile Set-output Values

When the module completes the Third Clamp Open Profile and
OPC03-B10 is set and SYS21-B14 is reset, it:

sets its outputs to the values listed below

sets status bit SYS22-B12

ignores SYS22 and these values and gives output control to the
Ejector Profile if SYS21-B14 is set

uses ramp rates TOC17 - 32 when changing outputs to these values

Use these values for pulling cores if applied before starting the
Clamp Open Slow Profile.

Word

Description

TOC33

Output #1 Set-output Value at End of Profile [19]

TOC34

Output #2 Set-output Value at End of Profile [19]

TOC35

Output #3 Set-output Value at End of Profile [19]

TOC36

Output #4 Set-output Value at End of Profile [19]