Status Word/Bit Descriptions

Publication 1771-6.5.88 – July 1997

SYS

Cycle Maximum Pressures

Word

Description

SYS49

Maximum Ram (Screw) Pressure During Last Cycle [01]
If bit patterns in MCC02 and MCC03 indicate that the module is connected to a ram (screw) pressure transducer but

not a clamp

position transducer, the module reports the highest ram (screw) pressure it detected since the last F-to-T transition of DYC02-B04.
If bit patterns in MCC02 and MCC03 indicate that the module is connected to a clamp position transducer, the module reports the
highest ram (screw) pressure it detected since the last F-to-T transition of DYC02-B00.

SYS50

Maximum Clamp Pressure During Last Cycle [02]
If bit patterns in MCC02 and MCC03 indicate that the module is connected to a clamp pressure transducer, the module reports the
highest clamp pressure it detected since last F-to-T transition of DYC02-B00.

SYS51

Maximum Ejector Pressure During Last Cycle [03]
If bit patterns in MCC02 and MCC03 indicate that the module is connected to a ejector pressure transducer, the module reports the
highest ejector pressure it detected since last F-to-T transition of DYC02-B00.

SYS52

Maximum Cavity (or System) Pressure During Last Cycle [04]
If bit patterns in MCC02 and MCC03 indicate that the module is connected to a cavity pressure transducer but

not a clamp position

transducer, the module reports the highest cavity pressure it detected since the last F-to-T transition of DYC02-B04.
If bit patterns in MCC02 and MCC03 indicate that the module is connected to both a cavity pressure transducer and a clamp position
transducer, the module reports the highest cavity pressure it detected since the last F-to-T transition of DYC02-B00.
If MCC02-B03, B04, B05 are all set, (inject/clamp/eject mode) the module reports the highest system pressure it detected since the
last F-to-T transition of DYC02-B00.
If MCC02-B03 is set with B04, B05 in opposite states (inject/clamp mode or clamp/eject mode) module will not report data in this word

Process Trace Data Collection Status

Word

Bit

Description

SYS53

Process Trace status

B00

Process Trace data collection in progress.

B01

Process Trace data collection complete.

B02 - B15

Open

SYS54

Process Trace data collection in progress

B00

The module is collecting trace data points 1 to 50.

B01

The module is collecting trace data points 51 to 100.

B02

The module is collecting trace data points 101 to 150.

B03

The module is collecting trace data points 151 to 200.

B04

The module is collecting trace data points 201 to 250.

B05

The module is collecting trace data points 251 to 300.

B06

The module is collecting trace data points 301 to 350.

B07

The module is collecting trace data points 351 to 400.

B08 - B15

Open

SYS55

Process Trace data collection done

B00

The module has collected trace data points 1 to 50.

B01

The module has collected trace data points 51 to 100.

B02

The module has collected trace data points 101 to 150.

B03

The module has collected trace data points 151 to 200.

B04

The module has collected trace data points 201 to 250.

B05

The module has collected trace data points 251 to 300.

B06

The module has collected trace data points 301 to 350.

B07

The module has collected trace data points 351 to 400.

B08 - B15

Open

SYS56

Open