Rockwell Automation 1771-QDC PLASTIC MOLD.MODULE User Manual

Page 207

Advertising
background image

3–31

Status Word/Bit Descriptions

Publication 1771-6.5.88 – July 1997

SYS

Word

Bit

Description

B08

= 0 Normal
= 1 High Screw Rotate Jog RPM
The module sets this bit when responding to command DYC01-B09 = 1 and real-time screw RPM equals or exceeds
JGC05.

B09

= 0 Normal
= 1 High Ram (Screw) Jog Pressure
The module sets this bit when responding to command DYC01-B10 = 1 or DYC01-B11 = 1 and real-time ram (screw)
pressure equals or exceeds JGC06.

B10

= 0 Normal
= 1 High Clamp Jog Pressure
The module sets this bit when responding to command DYC01-B12 = 1 or DYC01-B13 = 1 and real-time clamp pres-
sure equals or exceeds JGC07.

B11

= 0 Normal
= 1 High Ejector Jog Pressure
The module sets this bit when responding to command DYC01-B14 = 1 or DYC01-B15 = 1 and real-time ejector pres-
sure equals or exceeds JGC08.

B12

= 0 Normal
= 1 First Clamp Close Profile High Clamp Pressure
The module sets this bit when real-time clamp pressure equals or exceeds FCC57.

B13

= 0 Normal
= 1 Second Clamp Close Profile High Clamp Pressure
The module sets this bit when real-time clamp pressure equals or exceeds SCC57.

B14

= 0 Normal
= 1 Third Clamp Close Profile High Clamp Pressure
The module sets this bit when real-time clamp pressure equals or exceeds TCC57.

B15

= 0 Normal
= 1 Clamp Low Press Close Profile High Clamp Pressure
The module sets this bit when real-time clamp pressure equals or exceeds LPC57.

SYS06

High Pressure Alarm Status (Real Time)

The module sets alarm bits on a real-time basis. These bits are not latched.
You can inhibit each bit by setting its associated alarm setpoint to zero.

B00

= 0 Normal
= 1 Injection Profile High Ram (Screw) Pressure
The module sets this bit when real-time ram (screw) pressure equals or exceeds INC57.

B01

= 0 Normal
= 1 Injection Profile High Cavity Pressure
The module sets this bit when real-time cavity pressure equals or exceeds INC58.

B02

= 0 Normal
= 1 Pack Profile High Ram (Screw) Pressure
The module sets this bit when real-time ram (screw) pressure equals or exceeds PKC57.

B03

= 0 Normal
= 1 Pack Profile High Cavity Pressure
The module sets this bit when real-time cavity pressure equals or exceeds PKC58.

B04

= 0 Normal
= 1 Hold Profile High Ram (Screw) Pressure
The module sets this bit when real-time ram (screw) pressure equals or exceeds HDC57.

B05

= 0 Normal
= 1 Hold Profile High Cavity Pressure
The module sets this bit when real-time cavity pressure equals or exceeds HDC58.

B06

= 0 Normal
= 1 Pre-decompress Movement High Ram (Screw) Pressure
The module sets this bit when real-time ram (screw) pressure equals or exceeds PRC57.

B07

= 0 Normal
= 1 Plastication Profile High Ram (Screw) Pressure
The module sets this bit when real-time ram (screw) pressure equals or exceeds PLC57.

Advertising