Command Word/Bit Descriptions

Publication 1771-6.5.88 – July 1997

Notes: 1. For [ ] engineering units, see page 3.

2. When using the Inject/Clamp/Eject mode, all pressure readings are system pressure at input 2, except where noted.

First Clamp Close Profile Setpoints

Word

Description

CPC09

Segment 1 Velocity Setpoint [07] or [08]
if:

then the module:

you select Vel/Pos profile execution

controls clamp close speed to this setpoint after starting the First Clamp Close Profile
until clamp position reaches the larger of CPC11 or CPC61

CPC03-B14 is RESET

reads this parameter in percent velocity

CPC03-B14 is SET

reads it in in.(mm)/s

CPC10

Segment 1 Pressure Setpoint [02]
if:

then the module:

you select Press/Pos profile execution

controls clamp close pressure to this setpoint after starting the First Clamp Close Profile
until clamp position reaches the larger of CPC11 or CPC61

CPC11

End of Segment 1 Position Setpoint [14]

CPC12

Segment 2 Velocity Setpoint [07] or [08]
if:

then the module:

you select Vel/Pos profile execution

controls clamp close speed to this setpoint from the clamp position CPC11 until clamp
position reaches the larger of CPC14 or CPC61

CPC03-B14 is RESET

reads this parameter in percent velocity

CPC03-B14 is SET

reads it in in.(mm)/s

CPC13

Segment 2 Pressure Setpoint [02]
if:

then the module:

you select Press/Pos profile execution

controls clamp close pressure to this setpoint from the clamp position CPC11 until clamp
position reaches the larger of CPC14 or CPC61

CPC14

End of Segment 2 Position Setpoint [14]

CPC15

Segment 3 Velocity Setpoint [07] or [08]
if:

then the module:

you select Vel/Pos profile execution

controls clamp close speed to this setpoint from the clamp position CPC14 until clamp
position reaches the larger of CPC17 or CPC61

CPC03-B14 is RESET

reads this parameter in percent velocity

CPC03-B14 is SET

reads it in in.(mm)/s

CPC16

Segment 3 Pressure Setpoint [02]
if:

then the module:

you select Press/Pos profile execution

controls clamp close pressure to this setpoint from the clamp position CPC14 until clamp
position reaches the larger of CPC17 or CPC61

CPC17

End of Segment 3 Position Setpoint [14]

Second Clamp Close Profile Setpoints

Word

Description

CPC18

Segment 4 Velocity Setpoint [07] or [08]
if:

then the module:

you select Vel/Pos profile execution

controls clamp close speed to this setpoint after starting the Second Clamp Close Profile
until clamp position reaches the larger of CPC20 or CPC61

CPC03-B14 is RESET

reads this parameter in percent velocity

CPC03-B14 is SET

reads it in in.(mm)/s

CPC19

Segment 4 Pressure Setpoint [02]
if:

then the module:

you select Press/Pos profile execution

controls clamp close pressure to this setpoint after starting the Second Clamp Close
Profile until clamp position reaches the larger of CPC20 or CPC61

CPC20

End of Segment 4 Position Setpoint [14]

Advertising