2–23

Command Word/Bit Descriptions

Publication 1771-6.5.88 – July 1997

DYC

Word

Bit

Description

DYC04

Profile Status Block Clear Commands

B08

= 0 Normal
= 1 Clear CPS
A false-to-true transition of this bit forces the module to clear (zero) all words in its CPS buffer (except Master Status
Words CPS01 - CPS04). The module does not respond to this bit if the CPS is an unsupported status block based
upon Module I/O configuration.

B09

= 0 Normal
= 1 Clear IPS
A false-to-true transition of this bit forces the module to clear (zero) all words in its IPS buffer (except Master Status
Words IPS01 - IPS04). The module does not respond to this bit if the IPS is an unsupported status block based upon
Module I/O configuration.

B10

= 0 Normal
= 1 Clear HPS
A false-to-true transition of this bit forces the module to clear (zero) all words in its HPS buffer (except Master Status
Words HPS01 - HPS04). The module does not respond to this bit if the HPS is an unsupported status block based
upon Module I/O configuration.

B11

= 0 Normal
= 1 Clear PPS
A false-to-true transition of this bit forces the module to clear (zero) all words in its PPS buffer (except Master Status
Words PPS01 - PPS04). The module does not respond to this bit if the PPS is an unsupported status block based
upon Module I/O configuration.

B12

= 0 Normal
= 1 Clear OPS
A false-to-true transition of this bit forces the module to clear (zero) all words in its OPS buffer (except Master Status
Words OPS01 - OPS04). The module does not respond to this bit if the OPS is an unsupported status block based
upon Module I/O configuration.

B13

= 0 Normal
= 1 Clear EPS
A false-to-true transition of this bit forces the module to clear (zero) all words in its EPS buffer (except Master Status
Words EPS01 - EPS04). The module does not respond to this bit if the EPS is an unsupported status block based
upon Module I/O configuration.

B14

Open

B15

= 0 Normal
= 1 Clear PTS (Same description as B13, but for PTS.)

DYC05

ERC Re-initialize Commands

B00

= 0 Normal
= 1 Re-initialize First Clamp Close Profile ERC Values
A false-to-true transition of this bit forces the module to re-initialize the three ERC values associated with the First
Clamp Close Profile.

B01

= 0 Normal
= 1 Re-initialize Second Clamp Close Profile ERC Values
A false-to-true transition of this bit forces the module to re-initialize the three ERC values associated with the Second
Clamp Close Profile.

B02

= 0 Normal
= 1 Re-initialize Third Clamp Close Profile ERC Values
A false-to-true transition of this bit forces the module to re-initialize the three ERC values associated with the Third
Clamp Close Profile.

B03

= 0 Normal
= 1 Re-initialize Low Pressure Close Profile ERC Values
A false-to-true transition of this bit forces the module to re-initialize the two ERC values associated with the Clamp Low
Pressure Close Profile.

B04

= 0 Normal
= 1 Re-initialize Injection Profile ERC Values
A false-to-true transition of this bit forces module to re-initialize the 11 ERC values associated with the Injection Profile.

B05

= 0 Normal
= 1 Re-initialize Pack Profile ERC Values
A false-to-true transition of this bit forces the module to re-initialize the five ERC values associated with Pack Profile.

Advertising