Id = 14 – Rockwell Automation 1771-QDC PLASTIC MOLD.MODULE User Manual

Page 255

Advertising
background image

4–31

Programming Error Codes

Publication 1771-6.5.88 – July 1997

Error Code

Description

ID = 13

0233

PRC33 is out of range. Valid range is 00000

≤

PRC33

≤

09999

0234

PRC34 is out of range. Valid range is 00000

≤

PRC34

≤

09999

0235

PRC35 is out of range. Valid range is 00000

≤

PRC35

≤

09999

0236

PRC36 is out of range. Valid range is 00000

≤

PRC36

≤

09999

0237

PRC37 is out of range. Valid range is 00000

≤

PRC37

≤

09999

0238

PRC38 is out of range. Valid range is 00000

≤

PRC38

≤

09999

0239

PRC39 is out of range. Valid range is 00000

≤

PRC39

≤

09999

0240

PRC40 is out of range. Valid range is 00000

≤

PRC40

≤

09999

0405

PRC05 is out of range.
if:

then:

MCC13 and MCC14

PRC05 must be within 00000

≤

PRC05

≤

MCC14 – MCC13

are both non-zero

MCC13 is non-zero and

PRC05 must be within 00000

≤

PRC05

≤

MCC10 – MCC13

MCC14 is zero

MCC13 is zero and

PRC05 must be within 00000

≤

PRC05

≤

MCC14 – MCC09

MCC14 is non-zero

MCC13 and MCC14

PRC05 must be within 00000

≤

PRC05

≤

MCC10 – MCC09

are both zero

0457

PRC57 is out of range.
If non-zero, PRC57 must be within MCC17 < PRC57

≤

MCC18

0905

PRC05 is too large.
if:

then:

MCC13 and MCC14

PRC05 must be within MCC13 + PPC61 + PRC05

≤

MCC14

are both non-zero

MCC13 is zero and

PRC05 must be within MCC09 + PPC61 + PRC05

≤

MCC14

MCC14 is non-zero

MCC13 is non-zero and

PRC05 must be within MCC13 + PPC61 + PRC05

≤

MCC10

MCC14 is zero

MCC13 and MCC14

PRC05 must be within MCC09 + PPC61 + PRC05

≤

MCC10

are both zero

ID = 14

PLC – Plastication Configuration Block

Error Code

Description

ID = 14

0206

PLC06 is out of range. Valid range is 00000

≤

PLC06

≤

09999

0208

PLC08 is out of range. Valid range is 00000

≤

PLC08

≤

09999

0209

PLC09 is out of range. Valid range is 00000

≤

PLC09

≤

09999

0210

PLC10 is out of range. Valid range is 00000

≤

PLC10

≤

09999

0211

PLC11 is out of range. Valid range is 00000

≤

PLC11

≤

09999

0212

PLC12 is out of range. Valid range is 00000

≤

PLC12

≤

09999

0213

PLC13 is out of range. Valid range is 00000

≤

PLC13

≤

09999

0214

PLC14 is out of range. Valid range is 00000

≤

PLC14

≤

09999

0215

PLC15 is out of range. Valid range is 00000

≤

PLC15

≤

09999

0216

PLC16 is out of range. Valid range is 00000

≤

PLC16

≤

09999

0217

PLC17 is out of range. Valid range is 00000

≤

PLC17

≤

09999

0218

PLC18 is out of range. Valid range is 00000

≤

PLC18

≤

09999

0219

PLC19 is out of range. Valid range is 00000

≤

PLC19

≤

09999

0220

PLC20 is out of range. Valid range is 00000

≤

PLC20

≤

09999

0221

PLC21 is out of range. Valid range is 00000

≤

PLC21

≤

09999

Advertising