Chapter

3

Publication 1771-6.5.88 – July 1997

-

Status Word/Bit Descriptions

Status blocks report current status of molding machine operation.
Status blocks are returned from the QDC module to the PLC
processor by means of block transfer read (BTR) instructions in
software ladder logic.

Acronym:

Block ID
Binary: Decimal:

Description:

Page:

CLS

00001001

27

Clamp and Eject ERC Values Status Block

3-5

CPS

00000010

7

Clamp Close Profile Status Block

3-6

EPS

00000111

24

Ejector Profile Status Block

3-9

HPS

00000100

12

Pack/Hold Profile Status Block

3-11

IPS

00000011

9

Injection Profile Status Block

3-14

OPS

00000110

21

Clamp Open Profile Status Block

3-17

PPS

00000101

15

Plastication Profile Status Block

3-20

PTS

00001010

28

Process Trace Status Block

3-22

RLS

00001000

26

Inject ERC Values Status Block

3-24

SYS

00000001

1

System Status Block

3-25

The listings of status blocks use five types of data words:

Block ID

Bit-mapped

Stored-value

Open

Reserved

Block ID Word

The first word in each status block contains a binary number code in
the low byte that identifies the block. The PLC processor uses them
to identify status blocks received from the QDC module.

For all status block ID words, the high byte is identical to the high
byte of the system status word SYS01, and contains jog-execution
and power start-up status.

Bit-mapped Words

The first several words in any data block are bit-mapped. As the
QDC module monitors and detects changes in events of machine
cycles, it sets/resets or latches/unlatches status bits to inform the
PLC-5 processor that these events have occurred.

List of Status Blocks and
Block ID Codes

List of Data Words