Programming Error Codes

Publication 1771-6.5.88 – July 1997

Error Code

Description

ID = 7

0432

CPC32 is out of range.
if:

then:

MCC27 and MCC28

CPC32 must be within 00000

CPC32

MCC28 – MCC27

are both non-zero

MCC27 is non-zero and

CPC32 must be within 00000

CPC32

MCC24 – MCC27.

MCC28 is zero

MCC27 is zero and

CPC32 must be within 00000

CPC32

MCC28 – MCC23.

MCC28 is non-zero

MCC27 and MCC28

CPC32 must be within 00000

CPC32

MCC24 – MCC23

are both zero

0433

CPC33 is out of range. When CPC03-B14(16) = 1, a non-zero entry for CPC33 must be within
TCC45

CPC33

TCC46

0434

CPC34 is out of range. If non-zero, CPC34 must be within TCC41

CPC34

TCC42

0435

CPC35 is out of range.
if:

then:

MCC27 and MCC28

CPC35 must be within 00000

CPC35

MCC28 – MCC27

are both non-zero

MCC27 is non-zero and

CPC35 must be within 00000

CPC35

MCC24 – MCC27.

MCC28 is zero

MCC27 is zero and

CPC35 must be within 00000

CPC35

MCC28 – MCC23.

MCC28 is non-zero

MCC27 and MCC28

CPC35 must be within 00000

CPC35

MCC24 – MCC23

are both zero

0437

CPC37 is out of range. If non-zero, CPC37 must be within LPC41

CPC37

LPC42

0438

CPC38 is out of range.
if:

then:

MCC27 and MCC28

CPC38 must be within 00000

CPC38

MCC28 – MCC27

are both non-zero

MCC27 is non-zero and

CPC38 must be within 00000

CPC38

MCC24 – MCC27.

MCC28 is zero

MCC27 is zero and

CPC38 must be within 00000

CPC38

MCC28 – MCC23.

MCC28 is non-zero

MCC27 and MCC28

CPC38 must be within 00000

CPC38

MCC24 – MCC23

are both zero

0440

CPC40 is out of range. If non-zero, CPC40 must be within LPC41

CPC40

LPC42

0461

CPC61 is out of range.
if:

then:

MCC27 and MCC28

CPC61 must be within CPC62 < CPC61

MCC28 – MCC27

are both non-zero

MCC27 is non-zero and

CPC61 must be within CPC62 < CPC61

MCC24 – MCC27

MCC28 is zero

.

MCC27 is zero and

CPC61 must be within CPC62 < CPC61

MCC28 – MCC23

MCC28 is non-zero

MCC27 and MCC28

CPC61 must be within CPC62 < CPC61

MCC24 – MCC23

are both zero

0462

CPC62 is out of range. CPC62 must be within 00000

CPC62 < CPC61

0463

CPC63 is out of range.
If non-zero, CPC63 must be within MCC31 < CPC63

MCC32

0504

You have selected closed-loop Press/Pos execution for the First Clamp Close Profile by
CPC04-B01 = 0; however, your bit patterns in MCC02 and MCC03 indicate that the QDC
module does not have access to a connected clamp pressure transducer.

Advertising