Rockwell Automation 1771-QDC PLASTIC MOLD.MODULE User Manual

Page 83

Advertising
background image

2–17

Command Word/Bit Descriptions

Publication 1771-6.5.88 – July 1997

DYC

Word

Bit

Description

DYC02

B05

if:

then the module:

= 0 Normal
= 1 Execute Pack Profile
A false-to-true transition of this bit forces the module to do

one of the following, attempted in the order listed.

if:

then the module:

any of SYS07-B00 through B05 are SET

ignores any profile commands

SYS15-B11 is RESET

latches SYS13-B06

HPC11 is not zero

terminates any action in progress and
starts the Pack Profile

HPC11 is zero

terminates any action in progress and
starts the Hold Profile

B06

= 0 Normal
= 1 Execute Hold Profile
A false-to-true transition of this bit forces the module to do

one of the following, attempted in the order listed.

if:

then the module:

any of SYS07-B00 through B05 are SET

ignores any profile commands

SYS15-B11 is RESET

latches SYS13-B07

this bit (B06) is SET

terminates any action in progress and
starts the Hold Profile

B07

= 0 Normal
= 1 Execute Pre-decompression Movement
A false-to-true transition of this bit forces the module to do

one of the following, attempted in the order listed.

if:

then the module:

any of SYS07-B00 through B05 are SET

ignores any movement commands

either of the following are true:
– SYS15-B11 is RESET
– HPC03-B09 is SET and SYS15-B12 is RESET

latches SYS13-B08

all of the following are true:
– PRC05 equals zero or SYS15-B12 is RESET
– HPC03-B09 is RESET
– SYS15-B14 is RESET

latches SYS13-B09

PRC05 is not zero

terminates any action in progress and
starts the Pre-decompression Movement

both of the following are true:
– PRC05 is zero
– HPC03-B09 is SET

terminates any action in progress and
sets outputs to PRC33 - PRC40

either pair of the following are true:
– PRC05 is zero

or

– SYS15-B12 is RESET

– HPC03-B09 is RESET

– HPC03-B09 is RESET

terminates any action in progress and
starts the Plastication Profile