Command Word/Bit Descriptions

Publication 1771-6.5.88 – July 1997

Notes: 1. For [ ] engineering units, see page 3.

2. When using the Inject/Clamp/Eject mode, all pressure readings are system pressure at input 2, except where noted.

Ejector Full Advance Profile Setpoints

Word

Description

EPC09

Full Advance Segment 1 Velocity Setpoint [09] or [10]
if:

then the module:

you select Vel/Pos profile execution

controls ejector advance speed to this setpoint after starting any full advance portion of
the Ejector Profile until ejector position reaches the smaller of non-zero EPC11 or
EPC59

EPC03-B14 is RESET

reads this parameter in percent velocity

EPC03-B14 is SET

reads it in in.(mm)/s.

EPC10

Full Advance Segment 1 Pressure Setpoint [03]
if:

then the module:

you select Press/Pos profile execution

controls ejector advance pressure to this setpoint after starting any full advance portion
of the Ejector Profile until ejector position reaches the smaller of non-zero EPC11 or
EPC59

EPC11

End of Full Advance Segment 1 Position Setpoint [16]

EPC12

Full Advance Segment 2 Velocity Setpoint [09] or [10]
if:

then the module:

you select Vel/Pos profile execution

controls ejector advance speed to this setpoint during any full advance portion of the
Ejector Profile from the ejector position EPC11until ejector position reaches the smaller
of non-zero EPC14 or EPC59

EPC03-B14 is RESET

reads this parameter in percent velocity

EPC03-B14 is SET

reads it in in.(mm)/s

EPC13

Full Advance Segment 2 Pressure Setpoint [03]
if:

then the module:

you select Press/Pos profile execution

controls ejector advance pressure to this setpoint after during any full advance portion
of the Ejector Profile from the ejector position EPC11 until ejector position reaches
the smaller of non-zero EPC14 or EPC59

EPC14

End of Full Advance Segment 2 Position Setpoint [16]

EPC15

Full Advance Segment 3 Velocity Setpoint [09] or [10]
if:

then the module:

you select Vel/Pos profile execution

controls ejector advance speed to this setpoint during any full advance portion of the
Ejector Profile from the ejector position EPC14 until ejector position reaches EPC59

EPC03-B14 is RESET

reads this parameter in percent velocity

EPC03-B14 is SET

reads it in in.(mm)/s

EPC16

Full Advance Segment 3 Pressure Setpoint [03]
if:

then the module:

you select Press/Pos profile execution

controls ejector advance pressure to this setpoint during any full advance portion of the
Ejector Profile from the ejector position EPC14 until ejector position reaches EPC59

EPC17 - 20

Reserved

Ejector Tip Retract Profile Setpoints

Word

Description

EPC21

Tip Retract Velocity Setpoint [09] or [10]
if:

then the module:

you select Vel/Pos

controls ejector retract speed to this setpoint after starting any tip retract portion of the Ejector

profile execution

Profile until ejector position reaches the larger of EPC23 or EPC60

EPC03-B14 is RESET

reads this parameter in percent velocity

EPC03-B14 is SET

reads it in in.(mm)/s

EPC22

Tip Retract Pressure Setpoint [03]
if:

then the module:

you select Press/Pos

controls ejector retract pressure to this setpoint after starting any tip retract portion of the Ejector

profile execution

Profile until ejector position reaches the larger of EPC23 or EPC60