Rockwell Automation 1771-QDC PLASTIC MOLD.MODULE User Manual

Page 261

Advertising
background image

4–37

Programming Error Codes

Publication 1771-6.5.88 – July 1997

Error Code

Description

ID = 15

0736

PPC36 cannot be 00000 when PPC38 > 00000.

0739

PPC39 cannot be 00000 when PPC42 > 00000.

0740

PPC40 cannot be 00000 when PPC42 > 00000.

0743

PPC43 cannot be 00000 when PPC46 > 00000.

0744

PPC44 cannot be 00000 when PPC46 > 00000.

0747

PPC47 cannot be 00000 when PPC50 > 00000.

0748

PPC48 cannot be 00000 when PPC50 > 00000.

0815

PPC15 must be 00000 when PPC11 = 00000.

0816

PPC16 must be 00000 when PPC12 = 00000.

0819

PPC19 must be 00000 when PPC15 = 00000.

0820

PPC20 must be 00000 when PPC16 = 00000.

0823

PPC23 must be 00000 when PPC19 = 00000.

0824

PPC24 must be 00000 when PPC20 = 00000.

0827

PPC27 must be 00000 when PPC23 = 00000.

0828

PPC28 must be 00000 when PPC24 = 00000.

0831

PPC31 must be 00000 when PPC27 = 00000.

0832

PPC32 must be 00000 when PPC28 = 00000.

0835

PPC35 must be 00000 when PPC31 = 00000.

0836

PPC36 must be 00000 when PPC32 = 00000.

0839

PPC39 must be 00000 when PPC35 = 00000.

0840

PPC40 must be 00000 when PPC36 = 00000.

0843

PPC43 must be 00000 when PPC39 = 00000.

0844

PPC44 must be 00000 when PPC40 = 00000.

0847

PPC47 must be 00000 when PPC43 = 00000.

0848

PPC48 must be 00000 when PPC44 = 00000.

0961

PPC61 is too large.
if:

then:

MCC13 and MCC14

PPC61 must be within MCC13 + PPC61 + PRC05

MCC14

are both non-zero

MCC13 is zero and

PPC61 must be within MCC09 + PPC61 + PRC05

MCC14

is non-zero

MCC13 is non-zero and

PPC61 must be within MCC13 + PPC61 + PRC05

MCC10

MCC14 is zero

MCC13 and MCC14

PPC61 must be within MCC09 + PPC61 + PRC05

MCC10

are both zero

0962

PPC62 is too large.
if:

then:

MCC13 and MCC14

PPC62 must be within MCC13 + PPC61 + PPC62 + PSC05

are both non-zero

MCC14

MCC13 is zero and

PPC62 must be within MCC09 + PPC61 + PPC62 + PSC05

MCC14 is non-zero

MCC14

MCC13 is non-zero and

PPC62 must be within MCC13 + PPC61 + PPC62 + PSC05

MCC14 is zero

MCC10

MCC13 and MCC14

PPC62 must be within MCC09 + PPC61 + PPC62 + PSC05

are both zero

MCC10

1015

PPC15 is not in increasing positional order.
If non-zero, PPC15 must be greater than PPC11.

1019

PPC19 is not in increasing positional order.
If non-zero, PPC19 must be greater than PPC15.

1023

PPC23 is not in increasing positional order.
If non-zero, PPC23 must be greater than PPC19.