Rockwell Automation 1771-QDC PLASTIC MOLD.MODULE User Manual

Page 209

Advertising
background image

3–33

Status Word/Bit Descriptions

Publication 1771-6.5.88 – July 1997

SYS

Word

Bit

Description

B07

= 0 Normal
= 1 Clamp Open Profile Overtravel into Open Slow Zone
The module sets this bit during one of the first three Clamp Open Profiles when real-time clamp position equals or ex-
ceeds OPC61. The module resets this bit on next false-to-true transition of an action execution bit in DYC01 or DYC02.

B08-B15

Reserved for the module. Do not use.

SYS08

Alarm Status for Loss of Input Sensor (Real Time). The module sets alarm bits in real time. These bits are not latched.

B00

= 0 Normal
= 1 Loss of Ram (Screw) Position Sensor (Set MCC64 to inhibit)
If bit patterns in MCC02 and MCC03 indicate that the module is connected to a ram (screw) position transducer, the
module sets this bit when it detects a loss of signal input from the transducer.
When this bit is SET, the module stops any profile in progress and ignores any action execution command in DYC02
unless MCC64 is SET.

B01

= 0 Normal
= 1 Loss of Ram (Screw) Pressure Sensor (Set MCC64 to inhibit)
If bit patterns in MCC02 and MCC03 indicate that the module is connected to a ram (screw) pressure transducer, the
module sets this bit when it detects a loss of signal input from the transducer.
When this bit is SET, the module stops any profile in progress and ignores any action execution command in DYC02
unless MCC64 is SET.

B02

= 0 Normal
= 1 Loss of Clamp Position Sensor
If bit patterns in MCC02 and MCC03 indicate that the module is connected to a clamp position transducer, the module
sets this bit when it detects a loss of signal input from the transducer.
When this bit is SET, the module stops any profile in progress and ignores any action execution command in DYC02
unless MCC64 is SET.

B03

= 0 Normal
= 1 Loss of Clamp Pressure Sensor
If bit patterns in MCC02 and MCC03 indicate that the module is connected to a clamp pressure transducer, the module
sets this bit when it detects a loss of signal input from the transducer.
When this bit is SET, the module stops any profile in progress and ignores any action execution command in DYC02
unless MCC64 is SET.

B04

= 0 Normal
= 1 Loss of Ejector Position Sensor
If bit patterns in MCC02 and MCC03 indicate that the module is connected to a ejector position transducer, the module
sets this bit when it detects a loss of signal input from the transducer.
When this bit is SET, the module stops any profile in progress and ignores any action execution command in DYC02
unless MCC64 is SET.

B05

= 0 Normal
= 1 Loss of Ejector Pressure Sensor
If bit patterns in MCC02 and MCC03 indicate that the module is connected to a ejector pressure transducer, the module
sets this bit when it detects a loss of signal input from the transducer.
When this bit is SET, the module stops any profile in progress and ignores any action execution command in DYC02
unless MCC64 is SET.

B06

= 0 Normal
= 1 Loss of Ram (Screw) RPM Sensor (Set MCC64 to inhibit)
If bit patterns in MCC02 and MCC03 indicate that the module is connected to a screw RPM transducer, the module
sets this bit when it detects a loss of signal input from the transducer.
When this bit is SET, the module stops any profile in progress and ignores any action execution command in DYC02
unless MCC64 is SET.

B07

= 0 Normal
= 1 Loss of Cavity (or System) Pressure Sensor (Set MCC64 to inhibit)
If bit patterns in MCC02 and MCC03 indicate that the module is connected to a cavity pressure transducer, the module
sets this bit when it detects a loss of signal input from the transducer.
When this bit is SET, the module stops any profile in progress and ignores any action execution command in DYC02
unless MCC64 is SET.

B08-B15

Open