2–86

Command Word/Bit Descriptions

Publication 1771-6.5.88 – July 1997

Notes: 1. For [ ] engineering units, see page 3.

2. When using the Inject/Clamp/Eject mode, all pressure readings are system pressure at input 2, except where noted.

Unselected Valve Set-output Values

When the module starts the Plastication Profile, it:

sets its unselected outputs to the values listed below

ignores the unselected value of the selected output

uses ramp rates PLC17 - PLC32 to ramp unselected outputs

Word

Description

PLC09

Output #1 Set-output Value during Profile [19]

PLC10

Output #2 Set-output Value during Profile [19]

PLC11

Output #3 Set-output Value during Profile [19]

PLC12

Output #4 Set-output Value during Profile [19]

PLC13

Output #5 Set-output Value during Profile [19]

PLC14

Output #6 Set-output Value during Profile [19]

PLC15

Output #7 Set-output Value during Profile [19]

PLC16

Output #8 Set-output Value during Profile [19]

Output Ramp Rates

The module uses the following ramp rates when moving its outputs
from setpoint to setpoint during the Plastication Profile. The module
interprets a ramp rate of zero as a step function ramp (ramp disable).

Word

Description

PLC17

Output #1 Acceleration Ramp Rate during Profile [20]

PLC18

Output #2 Acceleration Ramp Rate during Profile [20]

PLC19

Output #3 Acceleration Ramp Rate during Profile [20]

PLC20

Output #4 Acceleration Ramp Rate during Profile [20]

PLC21

Output #5 Acceleration Ramp Rate during Profile [20]

PLC22

Output #6 Acceleration Ramp Rate during Profile [20]

PLC23

Output #7 Acceleration Ramp Rate during Profile [20]

PLC24

Output #8 Acceleration Ramp Rate during Profile [20]

PLC25

Output #1 Deceleration Ramp Rate during Profile [20]

PLC26

Output #2 Deceleration Ramp Rate during Profile [20]

PLC27

Output #3 Deceleration Ramp Rate during Profile [20]

PLC28

Output #4 Deceleration Ramp Rate during Profile [20]

PLC29

Output #5 Deceleration Ramp Rate during Profile [20]

PLC30

Output #6 Deceleration Ramp Rate during Profile [20]

PLC31

Output #7 Deceleration Ramp Rate during Profile [20]

PLC32

Output #8 Deceleration Ramp Rate during Profile [20]

End of Profile Set-output Values

When the module completes the Plastication Profile and PPC03-B08
is set, it:

sets its outputs to the following values

sets status bit SYS22-B08

uses ramp rates PLC17 - 32 when changing outputs to these values