Command Word/Bit Descriptions

Publication 1771-6.5.88 – July 1997

Notes: 1. For [ ] engineering units, see page 3.

2. When using the Inject/Clamp/Eject mode, all pressure readings are system pressure at input 2, except where noted.

Word

Description

Bit

DYC05

B06

= 0 Normal
= 1 Re-initialize Hold Profile ERC Values
A false-to-true transition of this bit forces the module to re-initialize the five ERC values associated with the Hold Profile.

B07

= 0 Normal
= 1 Open

B08

= 0 Normal
= 1 Re-initialize Plastication Profile ERC Values
A false-to-true transition of this bit forces module to re-initialize the 11 ERC values associated with Plastication Profile.

B09

= 0 Normal
= 1 Open

B10

= 0 Normal
= 1 Re-initialize First Clamp Open Profile ERC Values
A false-to-true transition of this bit forces the module to re-initialize the three ERC values associated with the First
Clamp Open Profile.

B11

= 0 Normal
= 1 Re-initialize Second Clamp Open Profile ERC Values
A false-to-true transition of this bit forces the module to re-initialize the three ERC values associated with the Second
Clamp Open Profile.

B12

= 0 Normal
= 1 Re-initialize Third Clamp Open Profile ERC Values
A false-to-true transition of this bit forces the module to re-initialize the three ERC values associated with the Third
Clamp Open Profile.

B13

= 0 Normal
= 1 Re-initialize Clamp Open Slow Profile ERC Values
A false-to-true transition of this bit forces the module to re-initialize the two ERC values associated with the Clamp
Open Slow Profile.

B14

= 0 Normal
= 1 Re-initialize Ejector Profile ERC Values
A false-to-true transition of this bit forces module to re-initialize the eight ERC values associated with the Ejector Profile.

B15

= 0 Normal
= 1 Re-initialize All ERC Values
A false-to-true transition of this bit forces the module to re-initialize the 62 ERC values associated with all profiles.

DYC06

Open

DYC07

Process Trace Commands

B00

Process trace data collection inhibited (examined at beginning of injection phase)

B01

Return injection position trace data in next PTS block

B02

Return trace #1 data in next PTS block

B03

Return trace #2 data in next PTS block

B04

Return trace #3 data in next PTS block

B05

Return trace #4 data in next PTS block

B06
-B14

Open

B15

Return phase/segment start information in next PTS block

DYC08

Process Trace Data Block Request

B00

Return trace data points 1 to 50 in next PTS block

B01

Return trace data points 51 to 100 in next PTS block

B02

Return trace data points 101 to 150 in next PTS block

B03

Return trace data points 151 to 200 in next PTS block

B04

Return trace data points 201 to 250 in next PTS block

B05

Return trace data points 251 to 300 in next PTS block

B06

Return trace data points 301 to 350 in next PTS block

B07

Return trace data points 351 to 400 in next PTS block